Topic: How to Save the Scanner Settings and Calibration Files
-
Calibration Files
The scanner calibration files are stored to the following files -
Win 7 & Vista:
\Users\Public\Public Documents\EDT XP: Documents and Settings\All Users\Shared Documents\EDT
-
- Filenames:
- EDT600C.CLB,
EDT900C.CLB
- EDT901.CLB,
EDTP960C.CLB
- EDT1200.CLB,
EDT1210.CLB etc
- where the numbers represent the
scanner model number.
-
- Note: The scanner driver will
prompt the user to calibrate the scanner when it is unable to access
the calibration file. You should ensure that the user account has
read/write access to the calibration file. If the prompt is
constantly displayed for a user, then (i) delete the existing
calibration file, and (ii) login as the user and perform a
calibration. You can also refer to this link for more information on
"How to
disable the calibration prompt"
Twain Initialization Files
- After each scan, the latest Twain scanner settings are saved to the
following files -
- A. BizCardReader 901, DX1210
Scanners:
- Win 7 & Vista: \Users\Username\AppData\Roaming\EDT
XP:
Documents and Settings\Username\Application Data\EDT
-
- B.
BizCardReader 600C, 900C, P960, DX1200 Scanners:
- Win 7 & Vista: \Users\Username\AppData\Local\Temp
XP: Documents and Settings\Username\LocalSettings\Temp
Filenames: EDT600C.INI, EDT900C.INI, EDT901.INI,
EDTP960C.INI EDT1200.INI,EDT1210.INI etc where the numbers represent the scanner model number.
NOTES:
1. For the system to "remember" the Twain scanning parameters, ensure
that you have
a. Read & Write access to the corresponding Twain
initialization file.
b. The Twain initialization file does not get deleted by the
OS or other program
2. To set/change the parameters in the ini file, the simplest method is
to start a scan. In the scan dialog box, select the desired scanning options. Then
perform a single scan with the selected parameters; this will cause the